Downloads
Download product brochures, technical datasheets, cybersecurity documentation, and regulatory validation guides for OptiZeus SCADA.
Free SCADA for one small machine
50 tags, 1 PLC, 5 screens, alarms and trends. Uses the Full Installer below - register for a free licence file.
Software & Updates
OptiZeus SCADA โ Update Patch
Recommended for every installation. 2.6.1.74: Free Edition (50 tags, 1 PLC, 1 station - register at optizeus.org/scada-free) and a demo plant that runs without a PLC; tag details from any alarm or screen object and Ctrl+K tag search; automated IQ / OQ validation with a signed PDF report; security (IEC 62443 SL1) - login banner, role checks on every change, HTTP can be redirected to HTTPS or switched off, a Security check page and a program file integrity check; fixed: the 2.6.1.71-73 patch installer did not copy two program folders. Reload stations once with Ctrl+F5. 2.6.1.73: alarm rationalization (ISA-18.2) - a Rationalization tab in Alarms and Events with cause, consequence, operator action, time to respond and priority for every alarm limit, review, approval and history, CSV export and import; alarms can be suppressed while a condition holds (for example a unit stopped), and an optional flood suppression keeps the first-out alarm; OEE downtime and recipe approval times in local time; imported calculated tags keep their formula; security - a disabled user is logged out at once, a changed role applies without a new login, security setting changes are in the audit trail. Reload stations once with Ctrl+F5. 2.6.1.72: Allen-Bradley EtherNet/IP - a PLC that cannot be reached (switched off, cable out, wrong address) no longer leaves a network connection open on every reconnect attempt, which over weeks used up the server resources; the attempts are no longer logged as errors. 2.6.1.71: historian v2 - a query interface for raw, plot, interpolated and aggregate history, archive reads in background threads, per-minute rollups for long time spans, and a local spool when the archive folder is unavailable; the historian handles 10 000 tags and more without running out of open files or memory; Alarm Performance (ISA-18.2) in Alarms and Events - alarm rates, floods, bad actors and chattering alarms with CSV export; an optional High Performance (ISA-101) object library; I/O list import from Excel or CSV, staged until Deploy; project versions - a version for every deploy, compare two versions, change report (CSV / PDF), rollback through staging; accounts lock after failed logins and administrators unlock them in Users; security fixes, and historian backups for administrators only. 2.6.1.70: history trends without a data log show the historian's data. 2.6.1.69: operators add pens to a history trend (+ Pen). Reload stations once with Ctrl+F5. 2.6.1.68: MicroLogix / SLC bit addresses on I, O, N and S files (I:0/1, O:0/3) read 0 or 1 instead of the whole word, and writing a bit changes only that bit; history trends get the full trend toolbar - live / pause, scroll back and forward, zoom and undo zoom, value cursor and Delta (time and value difference of every pen), a pen legend table with min / max / average, individual scales or isolated graphing, limit lines, X-Y plot, PNG snapshot and Print; history trend points are no longer drawn hours early. 2.6.1.67: visibility rules with bit set / bit clear and "any rule"; colour by state with blinking and outline per state, state from one bit and value ranges. 2.6.1.66: Allen-Bradley - two PLCs with the same tag address each keep their own value; Viewer Builder - converted pictures show their texts, colours and conditions to edit, and click actions get an Enabled when condition (tag, compare, bit set/clear, AND/OR, dimmed look); text objects with a font choice and several lines; values follow the object alignment and colour; visibility treats any non-zero value as on; screen scaling (stretch, keep proportions or fit width) per project and per screen; project export as configuration only or full, built on the server with a progress bar; FactoryTalk display import improvements. 2.6.1.65: Allen-Bradley writes open their PLC connection when needed - no more "the PLC is not connected" while the PLC reads fine, and a lost connection reconnects; small screen objects such as valve squares are no longer cut off; trend time axes start and end with the full date and time. 2.6.1.64: long-running station screens no longer grow in memory; history trends follow the background colours and show several pens, each in its own colour; faceplates and popups can fit the window; Config - Admin - Embedded Web serves a local web service under the OptiZeus address (with a Regenerate certificate button); staged tag updates deploy; the new-password request after a console reset survives a server restart. Reload stations once with Ctrl+F5. 2.6.1.63: forgotten admin password - RESET-ADMIN-PASSWORD.bat on the server PC sets a new one (recorded in the audit trail, new password required at the next login). 2.6.1.62: the desktop app opens reports again - batch reports, report previews and PDF / Excel exports in their own window; client workstations follow Admin - Electron (full screen, menu bar, kiosk) - install the patch on the server too. 2.6.1.61: the desktop app in full screen hides the File / Edit / View menu bar (it showed from the second start on). 2.6.1.60: a client PC whose server address could not be read no longer says "Node.js is not installed" - the desktop app reads every settings file and, when a client PC has no server address, asks for it once and remembers it. 2.6.1.59: client workstations - the desktop app on a PC installed as CLIENT ONLY opens the OptiZeus server on the network instead of waiting for a server on the same PC ("did not respond ... localhost:3004"); server addresses typed without https:// are corrected (the browser shortcut showed "file not found"); the patch updates a client PC without asking for the installation path. 2.6.1.58: the Config menu is shorter - Tags, UDT / Super Tags, Viewer Builder, Data Storage, Alarms, Reports and Recipes are under one Development menu; Server Redundancy shows a live drawing of both servers, the PLCs and the stations; the Language page counts the built-in translations and Auto Translate fills only the missing texts and explains when the online service refuses; Operation Manual edition 3.8. 2.6.1.57: server redundancy - exactly one server is active, the standby reads the PLCs but never writes and runs no alarms, notifications, schedules, scripts, batches or reports; alarms, events, the audit trail and batch records are copied between the servers and users from the active one; stations move to the active server by themselves; one Server Redundancy panel with a pair key. 2.6.1.56: Log snapshot buttons run their extra actions only after the values were saved. 2.6.1.55: current alarms - the alarm type line follows the chosen fields and the per-column font sizes apply to the alarm rows; the Current Alarms window shows the description as normal text, tag paths as written and its Time and Actions headers. 2.6.1.54: Allen-Bradley Logix number and bit writes work (the tag data type is learned first) and a failed write says why; current alarms list every waiting alarm, one row each with its description; Alarm History shows each alarm text in local time and searches dates over the whole history; Audit Trail columns no longer overlap; sessions left open by older versions are recorded as such; trend PDF pens print black or in dark colours. 2.6.1.53: audit trail records are never deleted without an archive - the retention purge first writes them to a checked archive file, listed and downloadable on the Audit Trail page; Hebrew text prints correctly in every PDF export. 2.6.1.52: no more Out of memory in the browser after auto-logoff, and a logged-out page no longer receives plant data; every logout is recorded in the audit trail with its reason (manual, auto-logoff, timeout, browser closed...); audit trail times shown in local time on the page, PDF and CSV, and a short audit retention needs a reason; view-only stations show a screen with live values after logout instead of the Login page, any change asks for a login; Audit Trail PDF export works again. 2.6.1.50: Allen-Bradley STRING tags (batch number, operator name) read and written as text, with Latin-1, Hebrew Windows-1255 or UTF-8 per PLC; back-to-normal SMS can be switched off, globally or per group. 2.6.1.49: popups opened by a tag - e.g. Batch finished successfully, shown on every station until the operator confirms; a Circle stays round at runtime; screen windows on a second monitor update live. 2.6.1.48: report exports open a Save As window to choose the folder or disk; Excel sheets with the same title are numbered from 1 (Batch Trend 1, 2 ...); the browser no longer offers to save the login password. 2.6.1.47: alarms per station also filter the alarm history, a station is recognised by its real address, and alarms a station is not shown cannot be acknowledged there. 2.6.1.46: alarms shown per station or user - a station can see only its own alarms in the list, the header counter and the history. 2.6.1.45: alarm clears are saved to the alarm history again and the notification log reaches SQL Server; clears follow the current notify groups; PLC DISCONNECTED banner at the top or bottom; header screens added from a searchable list. Note: since 2.6.1.44 ^ in expressions is XOR - use ** or pow() for powers. 2.6.1.44: the EtherNet/IP read cycle stays flat (a PLC that stays slow gets its connections reopened) and values not refreshed show as stale, with the read cycle per PLC on System Status; popup parameters so one faceplate serves many devices; a start screen per project, station and user with a Home button; alarm notify groups, day and night recipients, one SMS per person per alarm, InforU and HTTP SMS gateways with encrypted keys; bitwise operators in expressions; new historian tags take the project default interval; Query Table in Visual Reports that continues over pages; clickable web page objects; FactoryTalk display buttons imported with their commands; the patch also creates the desktop shortcuts. 2.6.1.43: popups draw their screen at its real size, complete and not stretched. 2.6.1.42: momentary push buttons with a server watchdog; MicroLogix / SLC file types and PLC error status corrected; historical charts read their own data log; popups at their own size, draggable, optional modal; browsers offer a reload after an update; data source passwords stored encrypted, SQL Server login with a Windows account. 2.6.1.41: Allen-Bradley - a red tag says why in Tag Monitor (tag not found, structure, unsupported type...) and is read again every 30 s; Browse starts structures and arrays at a member or element. 2.6.1.40: Viewer Builder box-select, move and Group keep working (the canvas no longer jumps when several objects are selected, and a moved selection stays selected); IO Check filter by PLC connection; Allen-Bradley tag browse says why it failed instead of Internal server error. 2.6.1.39: Screen Replay shows operator actions and alarms on a timeline; Log all tags button in the Viewer Builder. 2.6.1.38: the desktop app honours Full screen, Maximized and Menu bar from Admin - Electron. 2.6.1.37: Help - About shows the installed version. 2.6.1.36: Sequence of Events retention (auto-purge) and SOE on the Purge page; simulated tags no longer fill the SOE. 2.6.1.35: SQL Server data logs reconnect after a password change or database restore, and a saved data source applies at once; on-screen keyboard shows capitals with Caps and has a symbols key (@ # $ ...); Admin menus readable in the dark theme. 2.6.1.34: new IO Check page (Config - Admin) for testing the IO connected to the SCADA - search by tag and member, tick each tested signal, hide or show the checked ones, and a PDF report of every checked and unchecked tag; Allen-Bradley PLCs no longer disconnect after a Deploy; Tag Monitor with separate tag and member filters. 2.6.1.33: an OPC UA PLC whose values change all the time is no longer disconnected every ~2 minutes as stale (values flickered and recipe tables showed empty); array tables no longer change layout after a server restart or page reload. 2.6.1.32: screens no longer freeze for ~10 s when a PLC in the project cannot be reached - reconnecting runs in the background and every other PLC keeps updating. 2.6.1.31: SQL Server data sources can MOVE the oldest data into archive databases instead of deleting it - reports, trends, the Historian and batch reports read the archives directly; the size limit no longer deletes more than asked. 2.6.1.30: optional size limit for SQL Server data sources (the oldest data is deleted when the database is almost full, then the space can be given back); the touch keyboard on every page; reports in the desktop app retry instead of staying empty; VACUUM works right after purging sessions; S7 addresses with a leading %. 2.6.1.29: navigation works in layout panels again; after Deploy, open screens get new tag limits at once; Scan Rate per connection. 2.6.1.28: alarm notifications, reminders and shelving that work; audit-trail purge keeps the integrity check; historian fixes; Modbus 32-bit/float and S7 data types; per-connection scan rate; batch writes on every PLC protocol and approved recipes; a one-press Last batch report at the end of a recipe; scheduled reports; Deploy to Production, redundancy sync and auto-update with roll-back; the Operation Manual inside Help. Includes all fixes since 2.6.1.24. Run INSTALL-PATCH.bat; no need to re-download the full package.
OptiZeus SCADA โ Full Installer
Complete OptiZeus SCADA installation package (server, desktop application, and bundled Node.js runtime). Use this for a brand-new installation โ run SETUP.bat (option 2 CLIENT ONLY for an operator workstation: the desktop app and the browser shortcut both connect to the server address you enter). For an existing install, the Update Patch above is faster. Includes everything up to 2.6.1.74, the Operation Manual (edition 4.0) and the Client Workstation Guide (edition 2.1); the HTTPS certificate made at setup now names the PC and all its IP addresses, so station clients accept it.
OptiZeus SCADA โ Client Workstation Installer
For operator stations only: the OptiZeus desktop app and the browser shortcut, without the server, database or Node.js - about a third of the full installer. Copy it to the station PC, run SETUP-CLIENT.bat as administrator and enter the server address (and the backup server, if any). Window, full screen and kiosk settings come from the server. Later update patches update the station the same way as before.
Zeus PLC IDE โ Windows
Engineering environment for Zeus PLC controllers: IEC 61131-3 Structured Text, Ladder, FBD and SFC editors (any ST program, function block or method can be viewed as a live ladder diagram), data types (DUT), the function-block library (PID, S88, IO-Link and more), operator screens (a library of 1,081 plant symbols, animations, faceplates, keypad, alarm table, recipes, languages, a local HDMI display), a built-in simulator, online monitoring with write and force, workspaces that keep several controllers online together โ one program downloaded to many machines, a shared library and copying between projects โ redundant controller pairs with hot takeover, a whole-project cross-reference with checks, side-by-side compare with the controller, a company library, templates and controller backups. Includes the controller runtime โ Deploy runtime installs or updates a controller straight from the IDE. Self-contained โ unzip and double-click "Zeus PLC IDE.cmd"; nothing else to install.
Zeus PLC IDE โ Mac (Apple Silicon)
The same IDE for a Mac with an Apple M-series chip: editors, compiler, simulator, online monitoring and the controller runtime for Deploy runtime. macOS 11 or later. Unzip and double-click "Zeus PLC IDE.command"; the first time, allow it in System Settings โ Privacy & Security (Open Anyway).
Zeus PLC IDE โ Mac (Intel)
The same IDE for an Intel Mac. macOS 11 or later. Unzip and double-click "Zeus PLC IDE.command"; the first time, allow it in System Settings โ Privacy & Security (Open Anyway).
Zeus IPC-CM400200 Controller โ Datasheet
Technical datasheet of the Zeus IPC-CM400200 DIN-rail controller with either runtime - Zeus Native Runtime (Zeus PLC IDE) or Codesys V3.5 - compared side by side: processor and memory, power supply, interfaces, mechanical and environmental data, fieldbus protocols, watchdog, and ordering variants. 2 pages.
Marketing & Sales
Zeus IPC-CM400200 Controller โ Technical Datasheet
The Zeus IPC-CM400200 DIN-rail controller with either runtime - Zeus Native Runtime (Zeus PLC IDE) or Codesys V3.5 - compared side by side: processor and memory, power supply, interfaces, mechanical and environmental data, fieldbus protocols (EtherCAT, Profinet, EtherNet/IP, Modbus TCP, OPC UA), watchdog, and ordering variants. 2 pages.
Zeus PLC IDE โ Marketing Brochure
The Zeus PLC IDE and native runtime for the IPC-CM400200: advantages, screenshots, the Codesys vs Zeus runtime comparison, and a code example. 4 pages.
OptiZeus SCADA โ Marketing Brochure
Complete product overview with features, symbol library, industry applications, and pricing. 4 pages.
OptiZeus SCADA โ Product Overview
Visual brochure with screenshots and key highlights. Ideal for first impressions.
Technical Documentation
OptiZeus SCADA โ Operation Manual
The complete manual for OptiZeus SCADA 2.6.1.72 (edition 4.0): installation and licensing, a first project, PLC connections, tags and UDTs, the synoptic builder and animations, alarms and notifications, historian, recipes and ISA-88 batch, reports, KPI/OEE/SPC, users and security, embedded web services, backups, servers and client workstations, troubleshooting, validation, and six worked example projects. 444 pages.
OptiZeus SCADA โ Client Workstation Guide
Setting up operator workstations for OptiZeus SCADA 2.6.1.72 (edition 2.1): installing a CLIENT ONLY PC, the server address and HTTPS certificate, the desktop app and browser shortcut, window and kiosk settings from the server, start screen and alarms per station, updating clients, troubleshooting and a commissioning checklist. 20 pages.
Zeus PLC โ Controller Master Image Guide
How to build a master (golden) SD / eMMC image of a prepared Zeus PLC controller and produce new controllers from it, each with its own identity: preparing the reference unit, removing unit-specific data, reading, shrinking and checksumming the image, writing it, commissioning each new controller, and printable checklists. 27 pages.
Zeus PLC IDE โ Operation Manual
The complete manual for the Zeus PLC IDE and native runtime: installation, a first project, Structured Text / Ladder / SFC reference, data types, IO (Modbus TCP, EtherCAT, Profinet, IO-Link), online monitoring and debugging, alarms, OPC UA, EtherNet/IP, security, every built-in function and library block, redundant controller pairs, and 8 worked example projects. 592 pages.
OptiZeus SCADA โ Technical Datasheet
Full technical specs: protocols, visualization engine, 800+ symbol library, data management, system requirements, and integration.
OptiZeus SCADA โ Datasheet 2.6.1.71
Current technical datasheet: architecture, PLC protocols, historian v2, alarm management (ISA-18.2), High Performance (ISA-101) objects, engineering tools, security and compliance, capacities and system requirements.
Cybersecurity
Cybersecurity & Compliance Overview
Security architecture, authentication methods, RBAC, OWASP Top 10 mitigation, audit trail, e-signatures, and backup/DR.
Cybersecurity Assessment Report
Detailed cybersecurity assessment with vulnerability analysis, penetration test results, and remediation status.
Regulatory & Validation
21 CFR Part 11 Implementation Guide
How OptiZeus SCADA meets FDA 21 CFR Part 11 requirements: electronic records, signatures, audit trails, and system controls.
GAMP5 Validation Lifecycle
Complete GAMP5 validation approach: IQ/OQ/PQ protocols, risk assessment, traceability matrix, and validation summary.
Need Custom Documentation?
We can prepare custom technical proposals, validation packages, and cybersecurity assessments tailored to your specific requirements.