SCADA for small machines: what you really need
A small machine does not need a plant-wide system. It needs a clear screen, alarms the operator can trust, and a trend to see what happened last night. Here is how to plan it, and how to do it free.
What a small machine needs
- One PLC connection. Most machines and skids have one controller.
- A few screens. An overview, one or two detail screens, and an alarm page.
- Alarms and events. The operator sees what is wrong, acknowledges it, and you can see who did what.
- Trends and a short history. Enough to answer "what happened on the night shift?"
- One station. One PC or panel next to the machine.
The OptiZeus SCADA Free Edition covers exactly this: 50 tags, 1 PLC connection, 5 screens, 2 users, alarms and events, trends, and a historian that keeps 7 days.
Plan your 50 tags
Fifty tags go further than you think. A typical pump skid:
| Item | Tags |
|---|---|
| 2 pumps: running, fault, start command, speed | 8 |
| Tank level, pressure, flow, temperature | 4 |
| 4 valves: open, closed, command | 12 |
| Setpoints and mode selection | 6 |
| Machine state, alarm word, counters | 6 |
| Total | 36 |
Tips to save tags: pack status bits into one PLC word and use Bit tags only for the bits you show; keep calculations in the PLC; do not bring values to SCADA that nobody looks at.
Pick the protocol
OptiZeus reads the common small-machine controllers directly:
- Siemens S7-1200 and S7-1500 over the native S7 protocol
- Allen-Bradley CompactLogix and MicroLogix over EtherNet/IP
- Any Modbus TCP device
- OPC UA servers, MQTT, BACnet/IP and GE SRTP
Build it in an afternoon
- Install OptiZeus on the machine PC. Open the demo plant first: it runs without a PLC, so you can see screens, alarms and trends work.
- Add the PLC connection and click Test Connection.
- Create the tags and check them in the Tag Monitor: all values should show good quality.
- Draw the overview in the synoptic editor and bind the objects to the tags.
- Add alarm limits to the values that matter, then open a trend.
When the machine grows
If you need more tags, more stations, data logs, reports, recipes or text-message alarms, move to a paid edition. You import a new licence file; the project, screens and history stay as they are. Contact us for pricing.
Your data stays on your PC. OptiZeus runs locally and does not send process data to a cloud.
Try it free
OptiZeus SCADA Free Edition: 50 tags, 1 PLC, 5 screens, alarms and trends. Free for commercial use on one machine.